C L I M A X NEUTRON MONITOR DATA Jan 1953 - Dec 1991 Report Format for YEARLY File 60-Character Records =============================================================================== Column Fmt HEADER Description...for each day ------------------------------------------------------------------------------- 1 A1 STATION CODE (D=Climax, Colorado) 2 I1 MODIFICATION LEVEL of station 3- 4 A2 5- 6 I2 MONTH 7- 8 I2 DAY 9-12 I4 YEAR 13-16 I4 DAY-OF-YEAR COUNTER (1-365 or 366) 17-20 I4 SCALE FACTOR (tabulated hourly values multiplied by scale factor give true monitor count rates) 21 I1 FLAG (if equal to 0 or blank, 24 hourly data records follow; if equal to 1, dummy end-of-file records follow) 22-60 A39 Filled with zeros or with zeros and blanks =============================================================================== Column Fmt DATA Description...for each of the day's 24 hourly records ------------------------------------------------------------------------------- 1- 2 I2 UT HOUR (end time of interval over which counts were accumulated) 3- 4 I2 UT MINUTE (usually zero, since end time of data accumulation nor- mally within a few seconds of the hour) 5- 6 I2 UT SECONDS (usually zero, except for special events, when read- ings were not recorded within a few seconds of the hour) 7-10 I4 BAROMETRIC PRESSURE (10 x mm Hg; normally read on the half hour before the end time of accumulated counts; during periods of drastic change, pressure equals average for the hour) 11-15 I5 RAW COUNTS/HOUR* (A-section; not corrected for pressure) 16-20 I5 RAW COUNTS/HOUR* (B-section; not corrected for pressure) 21-34 I14 SPARES reserved for additional independent monitor sections 35 I1 FLAG (usually zero; if A/B ratio not normal owing to accumulator, voltage supply, section threshold, or tube efficiency problems, then A or B section is re-normalized to the other) 1=A-section count rate normalized to B-section 2=B-section count rate normalized to A-section 5=A-section rate high because of ground level event 6=B-section rate high because of ground level event 36-40 I5 CORRECTED COUNTS/HOUR* (A-section; corrected for pressure) 41-45 I5 CORRECTED COUNTS/HOUR* (B-section; corrected for pressure) 46-60 I15 SPARES reserved for additional independent monitor sections ------------------------------------------------------------------------------- *Missing data can occur for several reasons: (1) neither monitor section nor pressure could be read; (2) only pressure could be read; (3) one or both monitor sections, but no pressure, could be read. (4) only one monitor section and pressure could be read;